Characteristics

Operation and technical characteristics:
-Ventilation mode: Three speeds available plus automatic.
-Cooling mode
-Heating mode
-Dehumidification mode: To reduce relative humidity without turning the temperature down too much.
-AUTO/Automatic operation: This selects the operating mode based on pre-set parameters to provide the room with conditions of utmost comfort.
-TIMER/Timer setting: To preset the startup and the shutdown of the air conditioner.
-SLEEP/Night-time setting: To maintain optimum temperature during sleep periods.
-AUTORESTART/Automatic restarting: To automatically restart the system after an interruption of the power supply.
-AUTODIAGNOSIS/Maintenance: It indicates any functioning problems.
-Anti-dust filter: The indoor unit is equipped with a purification filter of the dust.
-Remote control: Liquid crystal display (LCD) with clear indication of functions.
-AIRSWING/Automatic movement of the vertical flap: Automatic adjustment of the vertical air flow direction.
CodeModelSound power dB(A)Capacity kW (Cool*/Heat**)EER / COPPower absorbed kW (Cool*/Heat**)
07009825X-ONE-0813 ON/OFF531,7 / 1,72,8 (A) / 3,1 (A)0,6 / 0,5
07009832X-ONE-1015 DC INVERTER553,1 / 3,13,2 (A+) / 3,3 (A)0,9 / 0,8

Notes

Refrigerant R410A (GWP = 2088) - Power supply (V-ph-Hz): 230-1-50 - Dimensions (WxHxD mm): 1030 x 555 x 170
(*) Cooling standard nominal conditions: internal temperature DB 27 °C - WB 19 °C - external temperature DB 35 °C
(**) Heating standard nominal conditions: internal temperature DB 20 °C - WB 15 °C - external temperature DB 7 °C